147
Appendix E:
CMOS Setup
Clearing CMOS settings
To clear the setup information stored in the CMOS, follow these steps.
1
Shut down and turn off the server.
2
Change the setting of the jumper on the motherboard to "Clear CMOS" and then
change the setting to "Normal."
3
Turn on the server.
After the CMOS is cleared, all setup information is lost and the following window
appears.
Press the <F1> key.
Follow these steps to reset the CMOS to its default settings.
4
Select "Load Setup Defaults" from the Setup menu.
JP1
1-2
Normal
2-3
Clear CMOS
CMOS Setting Wrong
CMOS/GPNV Checksum Bad
Press F1 to RUN SETUP
Press F2 to load defaults values and continue