2.12.2 Linking to Communication Circuit
The GRL100 can be provided with one of the following interfaces by order type and linked to a
dedicated optical fiber communication circuit or multiplexed communication circuit.
•
Optical interface (1310nm, SM, 30km class)
•
Optical interface (1550nm, DSF(Dispersion Shifted Fibre), 80km class) (*)
•
Optical interface (820nm, GI, 2km class)
•
Electrical interface in accordance with CCITT-G703-1.2.1
•
Electrical interface in accordance with CCITT-G703-1.2.2 and 1.2.3
•
Electrical interface in accordance with CCITT X.21
•
Electrical interface in accordance with RS422, RS530
Note (*): When using the 80km class optical interface, it is necessary to ensure that the received
optical power does not exceed
−
10dB, in order to avoid communication failure due to
overloading of the receive.
When testing in loop-back mode, for instance, the sending terminal should be connected
to the receiving terminal via an optical attenuator with 10 dB or more attenuation.
Even if the sending terminal is directly connected to the receiving terminal, the optical
transceiver will not be damaged, but communication failures may occur.
- Fibre Coupled Power:
−
5 to 0dBm
- Input Power Range:
−
34 to
−
10dBm
- Optical Damage Input Level: 3dBm
Alternative links to the telecommunication circuit are shown in Figure 2.12.2.1 (a) to (c).
(a) Direct link
(b) Electrical link via multiplexer
(c) Optical link via multiplexer
Figure 2.12.2.1 Link to Communication Circuit
O/E: Optical/Electrical converter
MUX: Multiplexer
Optical interface
GRL100
Twisted pair cable
with shield
<
60m
MUX
Optical
fibers
O/E
GRL100
Multiplexed circuit
Twisted pair cable with shield
<
60m
MUX
Electrical interface
GRL100
Optical fiber circuit
Optical interface
Содержание GRL100-101A
Страница 8: ... 7 6 F 2 S 0 8 3 5 6 7 4 Resumption of Service 220 6 7 5 Storage 220 7 Putting Relay into Service 221 ...
Страница 223: ... 222 6 F 2 S 0 8 3 5 ...
Страница 228: ... 227 6 F 2 S 0 8 3 5 Appendix B Signal List ...
Страница 256: ... 255 6 F 2 S 0 8 3 5 Appendix C Variable Timer List ...
Страница 258: ... 257 6 F 2 S 0 8 3 5 Appendix D Binary Output Default Setting List ...
Страница 269: ... 268 6 F 2 S 0 8 3 5 ...
Страница 270: ... 269 6 F 2 S 0 8 3 5 Appendix E Details of Relay Menu ...
Страница 279: ... 278 6 F 2 S 0 8 3 5 ...
Страница 288: ... 287 6 F 2 S 0 8 3 5 Appendix G Typical External Connection ...
Страница 326: ... 325 6 F 2 S 0 8 3 5 Appendix J Return Repair Form ...
Страница 330: ... 329 6 F 2 S 0 8 3 5 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Страница 331: ... 330 6 F 2 S 0 8 3 5 ...
Страница 332: ... 331 6 F 2 S 0 8 3 5 Appendix K Technical Data ...
Страница 343: ... 342 6 F 2 S 0 8 3 5 ...
Страница 344: ... 343 6 F 2 S 0 8 3 5 Appendix L Symbols Used in Scheme Logic ...
Страница 347: ... 346 6 F 2 S 0 8 3 5 ...
Страница 348: ... 347 6 F 2 S 0 8 3 5 Appendix M Multi phase Autoreclose ...
Страница 351: ... 350 6 F 2 S 0 8 3 5 ...
Страница 352: ... 351 6 F 2 S 0 8 3 5 Appendix N Data Transmission Format ...
Страница 358: ... 357 6 F 2 S 0 8 3 5 Appendix O Example of DIF and DIFG Setting ...
Страница 360: ... 359 6 F 2 S 0 8 3 5 Appendix P Programmable Reset Characteristics and Implementation of Thermal Model to IEC60255 8 ...
Страница 364: ... 363 6 F 2 S 0 8 3 5 Appendix Q IEC60870 5 103 Interoperability ...
Страница 377: ... 376 6 F 2 S 0 8 3 5 ...
Страница 378: ... 377 6 F 2 S 0 8 3 5 Appendix R Failed Module Tracing and Replacement ...
Страница 384: ... 383 6 F 2 S 0 8 3 5 Appendix S PLC Setting Sample ...
Страница 386: ... 385 6 F 2 S 0 8 3 5 Appendix T Ordering ...
Страница 392: ......