a-1 a-2
/2 Password
Input new password [ _ ]
Retype new password [ ]
/2 Description
1=Plant name 2=Description
/2 Communication
1=Address/Parameter
2=Switch
/3 Fault record 1/ 1
Fault locator 0=Off 1=On 1 _
/3 Event record 1/129
BITRN ( 0- 128) : 128 _
EV1 ( 0- 3071) : 0
EV2 ( 0- 3071) : 1
/1 Setting(change)
1=Password 2=Description 3=Comm
4=Record 5=Status 6=Protection
7=Binary input 8=Binary output 9=LED
/2 Record
1=Fault record 2=Event record
3=Disturbance record
4=Automatic test interval
/3 Disturbance record
1=Record time & starter
2=Scheme switch
3=Binary signal
/4 Record time & starter 1/ 3
Time ( 0.1- 3.0): 2.0 _ s
OCP-S( 0.5- 250.0): 10.0: A
OCP-G( 0.5- 250.0): 10.0: A
/4 Scheme switch 1/ 5
Trip trigger 0=Off 1=On 1 _
OCP-S 0=Off 1=On 1
OCP-G 0=Off 1=On 1
/3 Automatic test interval 1/ 1
Trip ( 1- 7): 1 _ days
/2 Binary output
1=IO#2 2=IO#3 3=IO#4
/2 Binary input 3/ 31
BISW 1 1=Norm 2=Inv 1
BISW 2 1=Norm 2=Inv 1
BISW 3 1=Norm 2=Inv 1
/3 Binary output (IO#2)3/12
BO1 ( 1, 2, 3, 4, 5, 6) AND,D
BO2 ( 1, 2, 3, 4, 5, 6) OR,
BO3 ( 1, 2, 3, 4, 5, 6) OR,D
/2 LED 3/ 4
LED1 ( 1, 309, 0, 0) AND, I
LED2 ( 0, 0, 0, 0) OR, I
LED3 ( 15, 16, 17, 0) OR, L
/3 Binary output (IO#4)3/12
BO1 ( 1, 2, 3, 4, 5, 6) AND,D
BO2 ( 1, 2, 3, 4, 5, 6) OR,
BO3 ( 1, 2, 3, 4, 5, 6) OR,D
: Confirmation trap
: Password trap
Password
Input password [_ ]
/2 *************
Change settings?
ENTER=Yes CANCEL=No
/3 Plant name [ _ ]
ABCDEFGHIJKLMNOPQRSTUVWXYZ()[]@_
←
→
abcdefghijklmnopqrstuvwxyz{}*/+-<=>
←
→
0123456789!”#$%&’:;,.^
← →
/3 Description [ _ ]
ABCDEFGHIJKLMNOPQRSTUVWXYZ()[]@_
←
→
abcdefghijklmnopqrstuvwxyz{}*/+-<=>
←
→
0123456789!”#$%&’:;,.^
← →
a-1 a-2
/3 Address/Parameter 1/ 15
HDLC ( 1- 32) : 1 _
IEC ( 0- 254) : 2
SYADJ (-9999- 9999) : 0 ms
/3 Switch 1/ 4
PRTCL1 1=HDLC 2=IEC103 2 _
232C 1=9.6 2=19.2 3=38.4 4=57.6 4
IECBR 1=9.6 2=19.2 2
/4 Binary signal 1/ 32
SIG1 ( 0- 3071) : 1 _
SIG2 ( 0- 3071) : 2
SIG3 ( 0- 3071) : 1
Содержание GRL100-101A
Страница 8: ... 7 6 F 2 S 0 8 3 5 6 7 4 Resumption of Service 220 6 7 5 Storage 220 7 Putting Relay into Service 221 ...
Страница 223: ... 222 6 F 2 S 0 8 3 5 ...
Страница 228: ... 227 6 F 2 S 0 8 3 5 Appendix B Signal List ...
Страница 256: ... 255 6 F 2 S 0 8 3 5 Appendix C Variable Timer List ...
Страница 258: ... 257 6 F 2 S 0 8 3 5 Appendix D Binary Output Default Setting List ...
Страница 269: ... 268 6 F 2 S 0 8 3 5 ...
Страница 270: ... 269 6 F 2 S 0 8 3 5 Appendix E Details of Relay Menu ...
Страница 279: ... 278 6 F 2 S 0 8 3 5 ...
Страница 288: ... 287 6 F 2 S 0 8 3 5 Appendix G Typical External Connection ...
Страница 326: ... 325 6 F 2 S 0 8 3 5 Appendix J Return Repair Form ...
Страница 330: ... 329 6 F 2 S 0 8 3 5 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Страница 331: ... 330 6 F 2 S 0 8 3 5 ...
Страница 332: ... 331 6 F 2 S 0 8 3 5 Appendix K Technical Data ...
Страница 343: ... 342 6 F 2 S 0 8 3 5 ...
Страница 344: ... 343 6 F 2 S 0 8 3 5 Appendix L Symbols Used in Scheme Logic ...
Страница 347: ... 346 6 F 2 S 0 8 3 5 ...
Страница 348: ... 347 6 F 2 S 0 8 3 5 Appendix M Multi phase Autoreclose ...
Страница 351: ... 350 6 F 2 S 0 8 3 5 ...
Страница 352: ... 351 6 F 2 S 0 8 3 5 Appendix N Data Transmission Format ...
Страница 358: ... 357 6 F 2 S 0 8 3 5 Appendix O Example of DIF and DIFG Setting ...
Страница 360: ... 359 6 F 2 S 0 8 3 5 Appendix P Programmable Reset Characteristics and Implementation of Thermal Model to IEC60255 8 ...
Страница 364: ... 363 6 F 2 S 0 8 3 5 Appendix Q IEC60870 5 103 Interoperability ...
Страница 377: ... 376 6 F 2 S 0 8 3 5 ...
Страница 378: ... 377 6 F 2 S 0 8 3 5 Appendix R Failed Module Tracing and Replacement ...
Страница 384: ... 383 6 F 2 S 0 8 3 5 Appendix S PLC Setting Sample ...
Страница 386: ... 385 6 F 2 S 0 8 3 5 Appendix T Ordering ...
Страница 392: ......