For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-
2192
62
25
Trim Dancer Control
Introduction
The G3’s dancer can be configured to act in two ways : independent of a master line reference (unlimited
frequency adjustment) or as a trim off of a master line reference (+/- 12.5% trim max). This guideline will
discuss the application of a dancer that trims the drive’s output frequency around a master line reference.
See Application Guideline 27, Independent Dancer Control for discussion of the other type of dancer
application. For this guideline, the drive is configured to follow a 4-20 mA reference. See related
Guideline 24 (PID) for more information.
Connections
TERMINAL STRIP
ST CC F CC
IV CC PP RX CC
Set the micro switch immediately to the right of the phone jack on the control board to the 5 volt or 10 volt position as appropriate for
your dancer. The other micro switch should be in the ‘I’ position for this example.
5/10 volt dancer position
4-20 mA master line reference
Programming
Group
Parameter
New Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
Frequency Setting Parameters Blind
1
UTILITY PARAMETERS
Feedback Parameters Blind
1
FUNDAMENTAL PARAMETERS #1
Maximum Output Frequency
60
(1)
FUNDAMENTAL PARAMETERS #1
Reverse Operation Disable Select
1
FREQUENCY SETTING PARAMETERS
RX Terminal Standard or Adjustable
1
FREQUENCY SETTING PARAMETERS
RX Reference Setting Point #1
(2)
FREQUENCY SETTING PARAMETERS
RX Reference Point #1 Frequency
0
FREQUENCY SETTING PARAMETERS
RX Reference Setting Point #2
100
FREQUENCY SETTING PARAMETERS
RX Reference Point #2 Frequency
60
FEEDBACK PARAMETERS
Feedback Control Selection
2
FEEDBACK PARAMETERS
Feedback Input Signal Selection
3
0.8
(3)
FEEDBACK PARAMETERS
Proportional Gain
0.5
(3)
FEEDBACK PARAMETERS
Integral Gain
0.0
(3)
FEEDBACK PARAMETERS
Lag Time Constant