For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-
2192
14
5
Motor Operated Pot1 (MOP)
Introduction
Frequently used for pendant stations on cranes, MOP control generates a speed reference for the G3 based on
how long a momentary contact is made. When the “increase” contact is made, the drive increases its output
frequency until the contact is released, at which point it maintains the current frequency. When the “decrease”
contact is made, the drive decreases its output frequency until the contact is released, at which point it
maintains the current frequency. A closure of the momentary “reset” contact ramps the drive down to zero
hertz. Do not use this control scenario with ACCEL and/or DECEL times greater than 10 seconds.
Connections
TERMINAL STRIP
ST CC F CC
S1 CC S2 CC S3 CC
Increase Decrease Reset
Programming
Group
Parameter
Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
Terminal Selection Parameters Blind
1
UTILITY PARAMETERS
Frequency Setting Parameters Blind
1
TERMINAL SELECTION PARAMETERS
Input Terminal Selection
1
TERMINAL SELECTION PARAMETERS
“S1” Input Terminal Function
34
TERMINAL SELECTION PARAMETERS
“S2” Input Terminal Function
35
TERMINAL SELECTION PARAMETERS
“S3” Input Terminal Function
36
FREQUENCY SETTING PARAMETERS
Frequency Priority Selection #1
5
Содержание G3
Страница 1: ...1 G3 Applications Workbook ...