E6581741
- 16 -
3.2.4.3.
fa23
(Communication command 2)
bit Function
0
1
Note
0 (Reserved)
-
-
-
1
Electric power quantity
reset
OFF Reset
Electric power quantity (
fe76
,
fe77
) reset
2 (Reserved)
-
-
-
3 (Reserved)
-
-
-
4 (Reserved)
-
-
-
5 (Reserved)
-
-
-
6 (Reserved)
-
-
-
7
Maximum deceleration
forced stop
Normal Enabled
-
8
Acceleration/decele-
ration selection 1
9
Acceleration/decele-
ration selection 2
00: Acceleration/deceleration 1
01: Acceleration/deceleration 2
10: Acceleration/deceleration 3
Select acceleration/deceleration
1-3 by combination of two bits..
AD1:
acc
,
dec
AD2:
f500
,
f501
AD3:
f510
,
f511
10 (Reserved)
-
-
-
11 (Reserved)
-
-
-
12
OC stall level switch
OC stall 1
OC stall 2
OC stall 1:
f601
OC stall 2:
f185
13 (Reserved)
-
-
-
14 (Reserved)
-
-
-
15 (Reserved)
-
-
-
Note: Set 0 to reserved bit.
Содержание EtherNet/IP Modbus IPE002Z
Страница 57: ...E6581741 56 Select the Module as below Select revision of drive Put in Name and IP address and press OK button ...
Страница 61: ...E6581741 60 Select the Download Once again select the Download ...
Страница 64: ...E6581741 63 ...
Страница 83: ...E6581741 82 13 3 Drive monitor Main menu Monitoring The state of the drive can be confirmed on this page ...
Страница 85: ...E6581741 84 Input the write value to popup window ...
Страница 89: ...E6581741 88 13 9 TCP IP statistics Main menu Diagnostics You can check TCP IP status on this page 88E ...