March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 45
2
260
Image
quality
control
Contrast voltage open-loop
control RMS value display
ALL
250
<0-999>
M
The default value of
development contrast
potential is displayed.
2
261
RMS value display of
development contrast volt-
age
ALL
300
<0-999>
M
The RMS value of devel-
opment contrast poten-
tial is displayed.
2
262
Image
quality
control
Background potential RMS
value display
ALL
100
<0-999>
M
The RMS value of the
background potential is
displayed.
[Unit: V]
2
263-0
Image
quality
control
RMS value
display of
open-loop
control
(Laser power
initial value)
1st laser
ALL
Refer to
contents
<0-1500>
M
The RMS value of the
laser power calculated in
the open-loop control is
displayed.
[Unit: µW]
<Default value>
e-STUDIO520 /
e-STUDIO600 /
e-STUDIO720: 665
e-STUDIO850: 304
10
263-1
2nd laser
ALL
304
<0-1500>
M
The RMS value of the
laser power calculated in
the open-loop control is
displayed.
[Unit: µW]
*
Valid only for
e-STUDIO850
10
264-0
Image
quality
control
Laser power
RMS value
display
1st laser
ALL
Refer to
contents
<0-1500>
M
The RMS value at the
regular operation is dis-
played.
[Unit: µW]
<Default value>
e-STUDIO520 /
e-STUDIO600 /
e-STUDIO720: 665
e-STUDIO850: 304
10
264-1
2nd laser
ALL
304
<0-1500>
M
The RMS value at the
regular operation is dis-
played.
[Unit: µW]
*
Valid only for
e-STUDIO850
10
265-0
Image
quality
control
Number of
times of
image quality
closed-loop
control correc-
tion
Develop-
ment con-
trast
voltage
correction
ALL
0
<0-99>
M
The number of times of
the development con-
trast voltage correction
performed is displayed.
10
265-1
Laser
power cor-
rection
ALL
0
<0-99>
M
The number of times of
laser power correction
performed is displayed.
10
268
Image
quality
control
Drum surface potential
sensor output
(Latest value)
(Low voltage)
ALL
0
<0-999>
M
The value of the main
charger grid bias mea-
sured with the drum sur-
face potential sensor is
displayed.
2
269
Drum surface potential
sensor output
(Latest value)
(High voltage)
ALL
0
<0-999>
M
2
Adjustment mode (05)
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......