e-STUDIO520/600/720/850 TROUBLESHOOTING
March 2005 © TOSHIBA TEC
5 - 94
5.1.13
Service call for others
[C360] Wire cleaner drive motor abnormality
(1)
Check if the main charger is not disconnected.
(2)
Check if the wire cleaner drive motor is driving.
(3)
Is the wire cleaner position detection switch working?
(4)
Replace the LGC board.
[C370] Wire cleaner drive motor abnormality
(1)
Is the transport belt unit working normally? (there is no extraneous material or toner clod).
(2)
Check if the connector of the transfer belt cam motor is not disconnected.
(3)
Check if the connector CN335 on the LGC board is disconnected.
(4)
Check if the fuse on the LVPS has blown.
(5)
Check if the transfer belt release detection sensor and transfer belt contact detection sensor is
working properly.
(6)
Replace the transfer belt cam motor.
(7)
Replace the LGC board.
[C940]
Engine-CPU is abnormality
[C970] High-voltage transformer leakage abnormality
(1)
Is the main charger installed securely?
(2)
Check if the spring of high-voltage supply contact point is deformed.
(3)
Check if the main charger wire is broken or the main charger grid is deformed.
(4)
Check if any foreign matters is on the main charger win or the main charger grid.
(5)
Replace the High-voltage transformer.
(6)
Replace the LGC board.
Is the “Call for Service” displayed even after the power is turned OFF and back ON?
!
NO
"
Leave it and see what happens.
YES
1) Check if the circuit pattern between the Engine-CPU and FROM is short circuited or
open circuited.
2) Replace the LGC board if this error occurs frequently.
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......