March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 9
2
2.1.2
Service call
Error code
Classification
Contents
Troubleshooting
C130
Paper feeding sys-
tem related ser-
vice call
1st drawer tray abnormality: The tray-up motor-1 does
not run normally or the 1st drawer tray does not move
normally.
(Feeding of any other drawer than the 1st drawer is pos-
sible.)
Ch.5.1.6
C140
2nd drawer tray abnormality: The tray-up motor-1 does
not run normally or the 2nd drawer tray does not move
normally.
(Feeding of any other drawer than the 2nd drawer is pos-
sible.)
Ch.5.1.6
C150
3rd drawer tray abnormality: The tray-up motor-2 does
not run normally or the 3rd drawer tray does not move
normally.
(Feeding of any other drawer than the 3rd drawer is pos-
sible.)
Ch.5.1.6
C160
4th drawer tray abnormality: The tray-up motor-2 does
not run normally or the 4th drawer tray does not move
normally.
(Feeding of any other drawer than the 4th drawer is pos-
sible.)
Ch.5.1.6
C180
Tandem LCF tray-up motor abnormality: The Tandem
LCF tray-up motor does not run normally or the Tandem
LCF tray does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Ch.5.1.6
C1A0
Tandem LCF end fence motor abnormality: The Tandem
LCF end fence motor does not run normally or the Tan-
dem LCF end fence does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Ch.5.1.6
C1C0
Option LCF tray-up motor abnormality: The Option LCF
tray-up motor does not run normally or the Option LCF
tray does not move normally.
(Feeding of any other drawer than the Option LCF is pos-
sible.)
Ch.5.1.6
C260
Scanning system
related service call
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when the power is
turned ON.
Ch.5.1.7
C270
Carriage home position sensor not turning OFF within a
specified period of time: The carriages do not shift from
their home position within a specified period of time.
Ch.5.1.7
C280
Carriage home position sensor not turning ON within a
specified period of time: The carriages do not reach their
home position within a specified period of time.
Ch.5.1.7
C360
Process related
service call
Wire cleaner drive motor abnormality: The wire cleaner
drive motor does not run normally or the charger wire
cleaner does not move normally.
Ch.5.1.13
C370
Transfer belt cam motor abnormality: The transfer belt
cam motor does not run normally when the power is
turned ON or the copying is started.
Ch.5.1.13
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......