e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
March 2005 © TOSHIBA TEC
2 - 24
2.1.4
Printer function error
Following codes are displayed at the end of the user name on the print job log screen
(when GM-1050/4010 or 2040 is installed)
Error code
Contents
Troubleshooting
4030
No printer kit / Invalid: When the printer kit or printer/scanner kit is not
installed, network print is performed after the trial period.
Ch.5.1.14 [ 6 ]
4031
HDD full during print: Large quantity image data by private print or invalid
network print are saved in HDD.
Ch.5.1.14 [ 6 ]
4032
Private-print-only error: Jobs other than Private print jobs cannot be per-
formed.
Ch.5.1.14 [ 6 ]
4033
Printing data storing limitation error: Printing with its data being stored to the
HDD temporarily (Proof print, Private print, Scheduled print, etc.) cannot be
performed.
Ch.5.1.14 [ 6 ]
4034
e-Filing storing limitation error: Printing with its data being stored to the HDD
(print and e-Filing, print to e-Filing, etc.) cannot be performed.
Ch.5.1.14 [ 6 ]
4035
Local file storing limitation error: Network FAX or Internet FAX cannot be sent
when "Local" is selected for the destination of the file to save.
Ch.5.1.14 [ 6 ]
4036
User authentication error: The user who intended to print a document is not
registered as a user.
Ch.5.1.14 [ 6 ]
A221
Print job cancellation: Print job (copy, list print, network print) is deleted from
the print job screen.
Ch.5.1.14 [ 6 ]
A222
Print job power failure: The power of the equipment is turned OFF during
print job (copy, list print, network print).
Ch.5.1.14 [ 6 ]
A290
Limit over error: The numbers of output pages have exceeded those speci-
fied with both of the department code and the user code at the same time.
Ch.5.1.14 [ 6 ]
A291
Limit over error: The number of output pages has exceeded the one speci-
fied with the user code.
Ch.5.1.14 [ 6 ]
A292
Limit over error: The number of output pages has exceeded the one speci-
fied with the department code.
Ch.5.1.14 [ 6 ]
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......