e-STUDIO520/600/720/850 TROUBLESHOOTING
5 - 61
5
[C280]
Carriage home position sensor not turning ON within a specified period of time
Remove the original glass and move the carriages to the paper feeding side. Turn ON the
power and check the following items.
Do the carriages make a big noise after they arrive at the home position?
l
l
l
l
l
l
!
YES
"
The carriage home position sensor is not turned ON.
1) Check if the connector of the sensor is disconnected.
2) Replace the carriage home position sensor.
3) Check if the conductor pattern on the SLG board is short circuited or
open circuited.
4) Replace the SLG board.
NO
The carriages are stopped at the home position and do not move.
1) Check if the connector pins are disconnected and the harnesses are short circuited or
open circuited.
2) Check if the conductor pattern on the SLG board is short circuited or open circuited.
3) Replace the SLG board.
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......