March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 11
2
C730
RADF related ser-
vice call
EEPROM error: EEPROM cannot be initialized normally
when the code 05-352 is performed or the data cannot be
read out of the EEPROM when the power is turned ON.
Ch.5.1.10
C820
Read sensor adjustment error: The read sensor cannot
be adjusted normally when the code 05-356 is performed.
Ch.5.1.10
C830
Original length detection sensor adjustment error: The
original length detection sensor cannot be adjusted nor-
mally when the code 05-356 is performed.
Ch.5.1.10
C840
Small original reverse sensor adjustment error: The small
original reverse sensor cannot be adjusted normally
when the code 05-356 is performed.
Ch.5.1.10
C850
Tray lift motor abnormality
Ch.5.1.10
C860
Large original exit sensor adjustment error: The large
original exit sensor cannot be adjusted normally when the
code 05-356 is performed.
Ch.5.1.10
C870
Temperature detection error
Ch.5.1.10
C940
Circuit related ser-
vice call
Engine-CPU abnormality
Ch.5.1.13
C970
Process related
service call
High-voltage transformer leakage abnormality: The high-
voltage leakage of the main charger is detected.
Ch.5.1.13
CA10
Laser optical unit
related service call
Polygonal motor abnormality: The polygonal motor does
not run normally.
Ch.5.1.11
CA20
H-sync detection error: Laser beam cannot be detected
at the SNS board.
Ch.5.1.11
CA30
Secondary scanning coarse adjustment error
[e-STUDIO850]
Ch.5.1.11
CA41
Window comparator abnormality (error during secondary
scanning control)
[e-STUDIO850
Ch.5.1.11
CA42
Sensor signal busy error (error during secondary scan-
ning control)
[e-STUDIO850]
Ch.5.1.11
CA43
Comparator abnormality
[e-STUDIO850]
Ch.5.1.11
CA44
Beam sensor detection error
[e-STUDIO850]
Ch.5.1.11
CA50
Laser power adjustment error
[e-STUDIO850]
Ch.5.1.11
CA90
Image data transmission error of SYS board: Communi-
cation error has occurred between the PLG board and
the SYS board.
[e-STUDIO850]
Ch.5.1.11
CAA0
Secondary scanning fine adjustment error: Secondary
scanning control by the galvanometer mirror does not
end normally.
[e-STUDIO850]
Ch.5.1.11
CAB0
Inter-page correction error of secondary scanning: Inter-
page secondary scanning control by the galvanometer
mirror does not end normally.
[e-STUDIO850]
Ch.5.1.11
CAC0
Primary scanning dot adjustment error: Primary scanning
control does not end normally.
[e-STUDIO850]
Ch.5.1.11
CAF0
Inter-page correction error of primary scanning: Inter-
page primary scanning control does not end normally.
[e-STUDIO850]
Ch.5.1.11
Error code
Classification
Contents
Troubleshooting
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......