e-STUDIO520/600/720/850 TROUBLESHOOTING
March 2005 © TOSHIBA TEC
5 - 156
5.3.5
HDD information display
This code displays the HDD operation history, which is recorded in the HDD, on the control panel. HDD
failure can be diagnosed or predicted with the information displayed.
1) Display
The following screen is displayed with setting code 08-670.
-
Items supported differ depending on the HDD manufacturer.
-
"---" is displayed on the VALUE, NAV and Worst columns if items are not supported.
2) Usage
The combination of the values of ID=05 and c5 is used to diagnose whether or not the HDD has a
physical failure when HDD failure is suspected (service call F100-180 or 120 occurred).
3) ID=05 and c5
Result
Description
Diagnosis
ID
VALUE
05
0
Low possibility of physical failure
HDD replacement
is not required.
c5
0
05
From 1 to 999
Defective sector has been reassigned and HDD is recovered.
HDD replacement
is not required.
c5
0
05
Any value
High possibility of defective sector existence. (There will be a
possibility of physical failure depending on the use of HDD.)
HDD replacement
is recommended.
c5
1 or more
05
Either one is at
least 1000.
High possibility of physical failure
HDD replacement
is recommended.
c5
05
All values are dis-
played as "-------".
High possibility of physical failure (A HDD connector, harness
or SYS board may be one of the causes.)
HDD replacement
is recommended.
c5
ID
Name
Description
Remarks
05
Re-allocated Sector Count
The number of sectors reassigned
This value tends to increase at
HDD failure.
c5
Current Pending Sector Count
The number of candidate sectors to
be reassigned
This value tends to increase at
HDD failure.
HDD manufacturer
Model name
HDD serial number
05/11
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......