e-STUDIO520/600/720/850 FIRMWARE UPDATING
March 2005 © TOSHIBA TEC
6 - 32
(6)
After the update is completed properly, the LED on the download jig blinks. The LED starts blink-
ing in approx. 30 sec. since the update starts. It is assumed that the update is failed if it does not
start blinking even though 1 min. has passed. In this case, turn OFF the power and check the fol-
lowing items. Then, clear the problem and restart updating from the beginning.
•
Is the download jig connected properly?
•
Is the ROM installed to the download jig properly?
•
Is the updating data written on the ROM of the download jig properly?
•
Do the download jig and the equipment operate properly?
(7)
Turn OFF the power, remove the download jig and install the cover plate.
(8)
In the FAX Clearing Mode, perform the “FAX Set up”.
•
Confirm the destination setting is correct in the Setting Mode (08).
08-201: Destination setting of the equipment
08-701: Destination setting of the FAX machine
•
Turn ON the power while [1] button and [*] button are pressed simultaneously.
•
Key in “100”.
•
Press the [START] button.
Notes:
If the equipment does not work properly after the operation (8), follow the procedure below and
then perform the “Clearing the image data” in the FAX Clearing Mode to erase the image data in
the memory.
•
Confirm the destination setting is correct in the Setting Mode (08).
08-201: Destination setting of the equipment
08-701: Destination setting of the FAX machine
•
Turn ON the power while [1] button and [*] button are pressed simultaneously.
•
Key in “102”.
•
Press the [START] button.
[B]
Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
was overwritten properly.
<Updating Engine ROM, PFC ROM>
08-903: Engine ROM version
08-906: PFC ROM version
<Updating Scanner ROM>
08-905: Scanner ROM version
<Updating Laser ROM>
08-904: Laser ROM version
<Updating RADF ROM>
08-907: RADF ROM version
<Updating Finisher ROM>
08-908: Finisher ROM version
<Updating Inserter ROM>
08-909: Inserter ROM version
<Updating FAX ROM>
08-915: FAX ROM version
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......