e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
March 2005 © TOSHIBA TEC
2 - 152
<<PM support mode related code>>
•
The management items at PM support mode can also be operated at setting mode (08).
The following items are displayed or set by using sub-codes at PM management setting in the table
below.
<Sub-codes>
0: Present number of output pages
- Means the present number of output pages.
1: Recommended number of output pages for replacement
- Means the recommended number of output pages for replacement.
2: Number of output pages at the last replacement
- Means the number of output pages at the last replacement.
3: Present driving counts
- Means the present drive counts (1 count = 2 seconds).
4: Recommended driving counts to be replaced
- Means the recommended drive counts for replacement (1 count = 2 seconds).
5: Driving counts at the last replacement
- Means the drive counts at the last replacement.
6: Present output pages for control
- Means the present number of output pages for controlling.
7: Present driving counts for control
- Means the present drive counts for controlling (1 count = 2 seconds).
*
For the cleaning web, this means the total feeding amount for controlling the cleaning web.
(1 count = 1 mm).
8: Number of times replaced
- Counts up when clearing the counter of each unit in the PM Support Mode Screen.
Notes:
•
Barring the exceptions, sub-code 3 is equivalent to sub-code 7.
•
Barring the exceptions, when the value of sub-code 3 is changed, the value of sub-code 7 is
also updated and vice versa.
•
When “0” is set at one of sub-codes 0, 3, 6 and 7, the rest of them are automatically updated
to “0”.
(Exceptions: 08-1228, 08-1252)
Содержание E-STUDIO520
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 6: ......
Страница 12: ......
Страница 24: ...e STUDIO520 600 720 850 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES March 2005 TOSHIBA TEC 1 12 ...
Страница 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Страница 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Страница 309: ...March 2005 TOSHIBA TEC e STUDIO520 600 720 850 PREVENTIVE MAINTENANCE PM 4 21 4 Fig 4 11 Finisher MJ 1027 1028 P1 P2 ...
Страница 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Страница 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Страница 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Страница 591: ......
Страница 592: ......