© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 49
2
526
Fuser
Pre-running time for first
printing (OHP film)
ALL
0
<0-15>
M
0: Invalid 1: 0 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
527-0
Fuser
Temperature
drop switching
time setting
during printing
(Side ther-
mistor)
The first
drop
ALL
20
<0-200>
M
This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000 sec.
later
4
527-1
The sec-
ond drop
ALL
30
<0-200>
M
4
527-2
The third
drop
ALL
48
<0-200>
M
4
527-3
The fourth
drop
ALL
75
<0-200>
M
4
535-0
Fuser
Temperature
drop control
setting during
printing
(Tempera-
ture/ Time)
Plain
paper
ALL
2
<0-20>
M
0: None
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
5: Pattern 5
6: Pattern 6
7: Pattern 7
8: Pattern 8
9: Pattern 9
10: Pattern 10
11: Pattern 11
12: Pattern 12
13: Pattern 13
14: Pattern 14
15: Pattern 15
16: Pattern 16
17: Pattern 17
18: Pattern 18
19: Pattern 19
20: Manual adjustment
4
535-1
Thick
paper
ALL
12
<0-20>
M
4
536-0
Fuser
Temperature
drop setting
during printing
(Center ther-
mistor)
The first
drop
ALL
1
<0-10>
M
This code is valid only
when “20” is set to 08-
535.
Setting value x -5°C:
from 0°C to -50°C
4
536-1
The sec-
ond drop
ALL
2
<0-10>
M
4
536-2
The third
drop
ALL
3
<0-10>
M
4
536-3
The fourth
drop
ALL
3
<0-10>
M
4
537-0
Fuser
Temperature
drop setting
during printing
(Side ther-
mistor)
The first
drop
ALL
1
<0-10>
M
4
537-1
The sec-
ond drop
ALL
2
<0-10>
M
4
537-2
The third
drop
ALL
3
<0-10>
M
4
537-3
The fourth
drop
ALL
5
<0-10>
M
4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
09/01
Содержание e-STUDIO163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 160: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 208: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 232: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 236: ......
Страница 237: ......