e-STUDIO163/166/203/206
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 12
[E87]
ADF open jam
Is the ADF opened?
YES
Remove the original, if any, and close the ADF.
NO
Is the ADF opening/closing sensor adjusted within the specified range?
NO
Adjust the ADF opening/closing sensor.
YES
Is the ADF opening/closing sensor working?
(Perform the input check: 03-[INTERRUPT]ON/[4]/[3])
l
l
l
l
l
l
l
l
l
NO
1) Check if the connector of the ADF opening/closing sensor is discon-
nected.
2) Check if the connector CN74 on the ADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are
open circuited.
4) Check if the conductor pattern on the ADF board is short circuited or
open circuited.
5) Replace the ADF opening/closing sensor.
6) Replace the ADF board.
YES
Replace the ADF board.
Содержание e-STUDIO163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 160: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 208: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 232: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 236: ......
Страница 237: ......