e-STUDIO163/166/203/206
TROUBLESHOOTING
5 - 21
5
5.2
Troubleshooting for the Image
1) Abnormality of image density / Gray balance
Fig. 5-1
Defective area
Step
Check items
Prescription
Density/Gray balance
1
Check the density/gray balance.
Adjust the density.
Printer section
2
Check test print image (07-113).
Go to step 4 if there is any problem
on image.
Scanner
3
Are the original glass and CIS unit
dirty?
Clean them.
Printed image
4
Is the image faded?
Perform troubleshooting for faded
image.
5
Is background fogging occurring?
Perform troubleshooting for back-
ground fogging.
6
Is there a blotch on the image?
Perform troubleshooting for blotched
image.
7
Is the image transferred normally?
Perform troubleshooting for abnor-
mal transfer.
Feeding direction
Image density
Gray balance
Содержание e-STUDIO163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 160: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 208: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 232: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 236: ......
Страница 237: ......