e-STUDIO163/166/203/206
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 2
(4) After about 2 minutes, all the “density LEDs” light and a value on the 7-segment LED automati-
cally starts changing.
Fig. 3-3
Note:
Note:
The output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
(5) After a short time, the value on the 7-segment LED becomes stable and all the “density LEDs”
are turned off.
(6) Check if the value on the 7-segment LED is within the range of 232 to 248 (i.e. the output voltage
range of the auto-toner sensor is 2.32 V to 2.48 V.).
(7) If the value is not within the range of 232 to 248, press the reproduction ratio buttons ([25%] /
[200%]) to adjust the value manually.
(8) Press the [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed on the 7-segment LED.
Fig. 3-4
(9) Turn the power OFF.
(10) Install the toner cartridge.
[INTERRUPT]
Содержание e-STUDIO163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 160: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 208: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 232: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 236: ......
Страница 237: ......