© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
TROUBLESHOOTING
5 - 25
5
5) Blurred image
Fig. 5-5
Defective area
Step
Check items
Prescription
Paper
1
Is the paper in the drawer damp?
Change paper. Avoid storing paper in
damp place.
Bedewed scanner
2
Is the scanner bedewed?
Clean the scanner.
Drum
3
Is the drum surface wet or dirty?
Wipe the drum with a piece of dry
cloth.
*
Do not use alcohol or other
organic solvents.
Ozone exhaust
4
Is the exhaust fan operating prop-
erly?
Check the connection of connector.
Replace the ozone exhaust fan.
5
Is the ozone filter stained or dam-
aged?
Replace the ozone filter.
Feeding direction
Содержание e-STUDIO163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 160: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 208: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 232: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 236: ......
Страница 237: ......