e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 8
10
00
Toner motor operation
(TONER MOTOR)
[Function]
When [OK (ENTER)/START] key is pressed, the toner motor is rotated for 30sec.
After completion of this process, the machine goes into the main code entry standby mode.
[Operation]
14
00
Cancel of trouble other than
U2 (TRBL CANC.)
[Function]
Used to cancel troubles other than U2.
∗
Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset.
[Operation]
16
00
U2 trouble cancel (U2 TRBL
CANC.)
[Function]
Used to cancel U2 trouble.
When [OK (ENTER)/START] key is pressed, check sum of the total counter in the EEPROM is rewrit-
ten and hardware reset is made.
[Operation]
20
01
Maintenance counter clear
(M-CNT CLR.)
[Function]
When [OK (ENTER)/START] key is pressed, the maintenance count value is cleared and "000,000" is
displayed.
[Operation]
21
01
Maintenance cycle setting
(M-CYCLE)
[Function]
The code of the currently set maintenance cycle value is displayed (initial display) and the set data
are saved.
[Operation]
22
01
Maintenance counter display
(M-CNT)
[Function]
The maintenance counter is displayed.
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
10-00 TONER MOTOR
EXECUTING...
1) Initial display
14-00 TRBL CANC.
CLEARED
1) Initial display
16-00 U2 TRBL CANC.
CLEARED
1) Initial display
20-01 M-CNT CLR.
CLEARED 000,000
Code
Setting
Remark
0
3,000 sheets
1
6,000 sheets
2
9,000 sheets
3
13,000 sheets
4
25,000 sheets
Default
5
Free (999,999 sheets)
1) The current set value is
displayed.
2) [
→
/10KEY]
2) [
←
/10KEY]
3) [OK (ENTER)/START]
21-01 M-CYCLE
4:25,000 ( 0-5 )
21-01 M-CYCLE
5:FREE ( 0-5 )
21-01 M-CYCLE
3:13,000 ( 0-5 )
21-01 M-CYCLE
5:FREE ( 0-5 )
1) Initial display
22-01 M-CNT
***,***
e-STUDIO162_151.book 8
ページ
2004年12月2日 木曜日 午後9時37分
Содержание e-studio 151
Страница 156: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 30 6 7 8 9 10 11 12 6 7 8 9 10 11 12 A B C D E F G H 1 1 ...
Страница 157: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 31 A 1 2 3 4 5 6 B C D E F G H 1 2 3 4 5 6 POWER SUPPLY 220V 240V ...
Страница 158: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 32 6 7 8 9 10 11 12 6 7 8 9 10 11 12 A B C D E F G H 1 1 ...
Страница 170: ...Memo ...
Страница 171: ...Memo ...
Страница 172: ...Memo ...
Страница 176: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...