e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 4
5. Sensors and switches
(With optional ADF/RADF installed)
No.
Name
Signal
Type
Function
Output
1
Scanner unit home position
sensor
MHPS
Photointerrupter
Scanner unit home position detection
"H" at home position
2
POD sensor
POD
Photointerrupter
Paper exit detection
"H" at paper pass
3
PPD2 sensor
PPD2
Photointerrupter
Paper transport detection 2
"L" at paper pass
4
Cassette detection switch
CED1
Micro-switch
Cassette installation detection
"H" at cassette insertion
5
PPD1 sensor
PPD1
Photointerrupter
Paper transport detection 1
"L" at paper pass
6
Door switch
DSW
Micro-switch
Door open/close detection
(safety switch for 24V)
1 or 0V of 24V at door open
7
ADF sensor
SPID/
SD SW
Photointerrupter
Paper entry detection
Cover open/close detection
"L" at paper pass
8
SPPD sensor
SPPD
Photointerrupter
Paper transport detection
"L" at paper pass
9
PD1 sensor
PD1
Micro-switch
Paper width detect
"H" at A4 size or less
"L" at A4 size or more
1
8
7
2
3
4
5
9
6
04_EXTER.fm 4
ページ
2004年12月22日 水曜日 午後1時41分
Содержание e-studio 151
Страница 156: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 30 6 7 8 9 10 11 12 6 7 8 9 10 11 12 A B C D E F G H 1 1 ...
Страница 157: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 31 A 1 2 3 4 5 6 B C D E F G H 1 2 3 4 5 6 POWER SUPPLY 220V 240V ...
Страница 158: ...e STUDIO162 162D 151 151D CIRCUIT DIAGRAM 14 32 6 7 8 9 10 11 12 6 7 8 9 10 11 12 A B C D E F G H 1 1 ...
Страница 170: ...Memo ...
Страница 171: ...Memo ...
Страница 172: ...Memo ...
Страница 176: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...