![Toshiba B-EX6 Series Скачать руководство пользователя страница 213](http://html.mh-extra.com/html/toshiba/b-ex6-series/b-ex6-series_maintenance-manual_424330213.webp)
10. ON LINE MODE
EM18-33031
10.10 LCD MESSAGES AND LED INCATIONS
10-25
23 SYSTEM
ERROR
●
When any abnormal operations as
below are performed, a system error
occurs.
(a) Command fetch from an odd
address
(b) Access to the word data from a
place other than the boundary of
the word data
(c) Access to the long word data from
a place other than the boundary of
the long word data
(d) Access to the area of 80000000H
to FFFFFFFFH in the logic space
in the user system mode.
(e) Undefined command placed in
other than the delay slot has been
decoded.
(f) Undefined command in the delay
slot has been decoded.
(g)
Command to rewrite the delay
slot has been decoded.
No No
24 DHCP CLIENT INIT…
●
●
Initializing DHCP CLIENT.
* Only when DHCP is enabled
--- ---
25
RFID WRITE
ERROR
●
The printer did not succeed in
writing data onto the RFID tag after
having retried for the specified
times.
Yes Yes
26
RFID ERROR
●
The printer cannot communicate
with the RFID module.
No
Yes
27 INPUT
PASSWORD
●
●
The printer is waiting for an entry of
password.
No No
28
PASSWORD
INVALID
●
●
A wrong password was entered
consecutively for three times.
No No
29 RFID
CONFIG
ERR
●
B-EX700-RFID-U2-EU/US-R, B-
EX700-RFID-U4-EU/US-R, U4
module preinstall model only
RFID module’s destination code is
not specified.
No No
30
LOW BATTERY
(Refer to Notes 4 and 5)
●
RTC battery is low.
No Yes
31
INTERNAL COM
ERR
●
●
A hardware error has occurred in
the internal serial interface.
No No
Explanation of symbols
Symbol Explanation
Range
: ON
---
: Blinking
---
: OFF
---
%%,%%%,%%%: Remaining memory size of the external USB
memory
0 to 09,999,999 (Kbyte)
####:
Remaining memory size for PC command
storage area in the internal memory
0 to 3072 (Kbyte)
&&&&:
Remaining memory size for writable
character storage area
0 to 3147 (Kbyte)