5. SYSTEM MODE
EM18-33031
5.10 RFID
5-69
5.10.2.2
COUNTRY
When the module type is set to “U4”, the country code of the currently installed module is displayed.
If the module type is set to other than “U4”, “INVALID” is displayed.
It is possible to change the country setting only when the module type is set to “U4” and the actually
installed module is US or EU or AU. However, this menu is password-protected because changing the
country setting causes the output frequency to change.
The following message is displayed depending on the module type setting, the mounted module type,
and the module mount condition.
Module Type
parameter
Module type and status
Message
NONE
No module installed.
NONE
U4
No module installed.
No RFID Module
B-EX706-RFID-U4-R
B-EX706-RFID-U4-EU-R
B-EX706-RFID-U4-US-R
B-EX706-RFID-U4-AU-R
No country
setting
Need Setting for use
[ENTER] for Setting
*1: Selectable country codes differ depending on the RFID module type. Multiple country codes may be
displayed when setting a country code, but be sure to select the country where the RFID module is used.
Setting a different country code is prohibited.
5.10.2.3 TAG
Selectable tag types vary according to the module setting.
The number in the table indicates the scroll line number.
NONE
H1
H2
U2/U4
NONE
1 1 1 1
I-Code 2
2
Tag-It 3
3
C220 4
4
ISO15693 5
5
2
C210 6
6
C240 7
7
C320 8
8
EPC C1 Gen2
9
2