5. SYSTEM MODE
EM18-33031
5.5 SET PARAMETERS
5-41
NOTE
: “Generic” is a setting for securing the print quality equivalent to that of the B-SX, but it is not effective
at the print speed of 10 ips or faster. If 10 ips or faster print speed is specified, the printer operation
is not guaranteed. For details, refer to the Supply Specification for the B-EX6T1 series.
5.5.25.2 DIRECT
・
NORM: Normal
・
rsv1: (Reserved1)
・
rsv2: (Reserved2)
・
rsv3: (Reserved3)
・
rsv4: (Reserved4)
・
rsv5: (Reserved5)
・
rsv6: (Reserved6)
・
rsv7: (Reserved7)
・
rsv8: (Reserved8)
・
rsv9: (Reserved9)
NOTE
: If “CN” is selected for the parameter clear destination, the ENERGY TYPE parameter is not
displayed on the menu and unable to be set in the system mode and user system mode. However,
the initial value will be set after a RAM clear, so it is printed on the maintenance counter/parameter
settings print label.
5.5.26 TONE ADJ. <T>
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+20 -20 1 Decimal
Exist 2 0 None
Step
NOTES
:
1. Setting a value in the positive (+) direction, the print tone becomes darker. And, setting a value in the
negative (-) direction, the print tone becomes lighter.
+20
←
(Darker)
←
0
→
(Lighter)
→
-20
2. The print tone fine adjustment value (thermal transfer) is the sum of the fine adjustment values set in the
system mode (by key operation) and set by command (from the PC). The max. value is -20 to +20. If the
value exceeds the print head rating, it is automatically corrected.
3. The factory default is +0step.
5.5.27 TONE ADJ. <D>
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+20 -20 1 Decimal
Exist 2 0 None
Step
NOTES
:
1. Setting a value in the positive (+) direction, the print tone becomes darker. And, setting a value in the
negative (-) direction, the print tone becomes lighter.
+20
←
(Darker)
←
0
→
(Lighter)
→
-20
2. The print tone fine adjustment value (thermal transfer) is the sum of the fine adjustment values set in the
system mode (by key operation) and set by command (from the PC). The max. value is -20 ~ +20. If the
value exceeds the print head rating, it is automatically corrected.
3. The factory default is +0.