5. SYSTEM MODE
EM18-33031
(Revision Date: Nov., 2017)
5.7 SENSOR
5-50
5.7 SENSOR
Contents of SENSOR menu
Menu item
<4>SENSOR
TEMPERATURE
ADJUSTMENT
THRESHOLD
SELECT
THRESHOLD
LEVEL
5.7.1 TEMPERATURE
The ambient temperature and print head temperature are displayed.
Only when the temperature is below zero, the symbol of minus (-) is displayed.
The display is updated every 200 msec.
The range of each temperature is below.
Outer temperature
-20 to 100
Head temperature
-20 to 100
5.7.2 ADJUSTMENT
The menu structure of ADJUSTMENT menu
Menu item
<2>SET PARAMETERS
SENSOR
ADJUSTMENT
REFLECTIVE
SENSOR
TRANSMISSIVE
SENSOR
PAPER
END
LEVEL
RIBBON
SENSOR
5.7.2.1 REFLECTIVE SENSOR
The sensor level of the reflective sensor is registered.
Place the tag paper to be used on the reflective sensor so that the sensor can detect a print (blank)
area.
The display of the currently detected value is updated every 200 msec.
Hold down the [ENTER] key for 3 seconds or more.
When the registration of the “print area level” is completed, “Adjust Complete” is displayed and an
asterisk (*) is shown on the right side of the voltage.
If the registration failed due to sensor failure, “SENSOR ERROR” is displayed and the ERROR LED
turns on. The ERROR LED turns off when the upper-level menu is displayed.
The setting range is as below.
Reflective sensor
0.0V to 5.0 V