10. ON LINE MODE
EM18-33031
10.6 MANUAL THRESHOLD SETTING
10-11
10.6.2 Threshold Setting Operation Example
1. Online mode:
Online state
B-EX4T1
C1.6
PRINTED
000000
IP:192.168.010.020
ONLINE
↓
Press the [PAUSE] key.
2. Online mode:
Pause state
PAUSE
↓
Hold down the [PAUSE] key for 3 seconds.
3. Threshold setting:
Media sensor selection
SELECT MEDIA SENSOR
▴
1)REFL.(PRE-PRINT)
2)TRANS.(PRE-PRINT)
▾
Move the cursor with the [UP] or
[DOWN] key.
↓
Press the [ENTER] key.
4. Threshold setting:
Waiting for the media to be
loaded
1)REFL.(PRE-PRINT)
THRESHOLD MODE
▴ Load the media.
Press the PAUSE Key
▾ to start the
Scroll the screen with the [UP] or
[DOWN] key.
↓
Press the [PAUSE] key.
5. Threshold setting:
Calibration
1)REFL.(PRE-PRINT)
THRESHOLD MODE
Calibrating
Hold down the [PAUSE] key to keep
feeding the media.
↓
Release the [PAUSE] key. (Media feed stops.)
When the judgment result is OK, go to “6. Threshold setting”.
When the judgment result is NG, go to “7. Threshold setting”.
6. Threshold setting:
6a.
Judgment result: OK
(After threshold setting)
1)REFL.(PRE-PRINT)
Result: OK (Mid.)
Threshol
Baseline
Retry FEED
Detail▶
[FEED] key
“3. Media sensor selection.” (Threshold is set again.)
[ENTER] key
“2. Pause state.” (Threshold setting is completed.)
[RIGHT] key
“6b.
Details of the r
esult.” (Result and the threshold value are displayed.)
6b. Details of the r
esult
1)REFL.(PRE-PRINT)
Peak
: 3.7V
Threshold : 2.7V
Baseline : 1.3V
◀Result
Adjust▶
↓
Press the [RIGHT] key.