5. SYSTEM MODE
EM18-33031
5.5 SET PARAMETERS
5-39
5.5.23 BACK ADJ.
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+9.9 -9.9 0.1
Decimal
Exist 1
1 None mm
+0.0mm
+3.0mm
-3.0mm
NOTES
:
1. The reverse feed amount fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is ±9.9mm.
2. There may be cases where a label is not returned to the home position depending on the print conditions,
even if the media is fed backward for the same amount as the forward feed. For issuing media with the
media sensor, if the label pitch is almost the same as the distance between the print head and the media
sensor (75.5 mm), the media may not be returned to the home position when operations including a
reverse feed (such as cut issues, strip issues, automatic forward feed) are performed. It may result in an
error. To prevent this error from occurring, increase the reverse feed amount by performing the reverse
feed amount fine adjustment in the + direction.
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)