Note:
To seal the tank, close the cover and
rotate the front half clockwise.
Important:
After filling the tank for the first
time, check the tank straps for any play.
Tighten as necessary.
Inspecting the Tank Straps
Service Interval:
Before each use or daily—Check
the tank straps.
Important:
Overtightening the tank strap
fasteners can result in deforming and damaging
the tank and straps.
Important:
Whenever possible, do not use
reclaimed water (gray water) in the spray tank.
1.
Fill the main tank with water.
2.
Check to see if there is any movement between
the tank straps and the tank (
).
g028263
Figure 28
1.
Rear tank strap
4.
Forward tank strap
2.
Bolt
5.
Front of the machine
3.
Flanged locknut
3.
If the tank straps fit loose to the tank, tighten the
flanged locknuts and bolts at the top of straps
until the straps are flush with the surface of the
tank (
).
Note:
Do not overtighten the tank strap
hardware.
Calibrating the
Section-Bypass Valves
Manual Mode Only
Important:
When operating in application rate
mode, you must set the section-bypass valves to
the closed position.
Important:
Whenever possible, do not use
reclaimed water (gray water) in the spray tank.
Before using the sprayer for the first time, whenever
you change the nozzles, or as needed, calibrate the
sprayer flow, speed, and set the section bypass.
Important:
Select an open flat area to perform
this procedure.
Preparing the Machine
1.
Fill the spray tank halfway with clean water.
2.
Lower the spray sections.
3.
Engage the parking brake.
4.
Set the spray control switch to manual.
5.
Set the 3 section switches to the O
N
position,
but leave the master section switch in the O
FF
position.
6.
Set the spray-pump switch to the O
N
position,
and turn on the agitation.
7.
On the InfoCenter, navigate to the Calibration
screen and select Test Speed; refer to
Simulating a Test Speed in the
Software Guide
for the Multi Pro 5800-D and 5800-G turf sprayer
with ExcelaRate spray system.
A.
Press buttons 3 or 4 to raise or lower the
simulated speed to 5.6 km/h (3.5 mph).
B.
Press button 4 to toggle O
N
test speed
simulation.
C.
Press button 5 to save and exit the
TEST
SPEED
screen.
Adjusting the Section Bypass
Valves
1.
Using the application-rate switch, adjust the
application rate according to the table that
follows.
Nozzle Application Rate Table
Nozzle Color
SI (Metric)
English
Turf
Yellow
159 L/ha
17 gpa
0.39 gpk
Red
319 L/ha
34 gpa
0.78 gpk
Brown
394 L/ha
42 gpa
0.96 gpk
Gray
478 L/ha
51 gpa
1.17 gpk
White
637 L/ha
68 gpa
1.56 gpk
Blue
796 L/ha
85 gpa
1.95 gpk
Green
1,190 L/ha
127 gpa
2.91 gpk
2.
Turn off the left-section switch and adjust the
section-bypass knob (
) until the rate
displayed is at the previous level according to
the table.
28
Содержание Multi Pro 41394
Страница 11: ...decal139 3065 139 3065 1 Read the Operator s Manual 11...
Страница 92: ...Schematics g034336 Sprayer System Schematic Rev DWG 131 9559 Rev A 92...
Страница 93: ...Notes...
Страница 94: ...Notes...