Spray-Pump Switch
The spray-pump switch is located on the center
console to the right of the seat (
). Toggle this
switch forward to run the spray pump or rearward to
stop the pump. When the switch is turned on, a light
on the switch illuminates.
Important:
Engage the spray-pump switch only
when the engine is at
LOW IDLE
to avoid damaging
the pump drive.
Boom-Section Lift Switches
The boom-section lift switches are located on the
center console to the right of the seat and used to
raise or lower the left and right boom sections (
Master Section Switch
The master section switch is located on the center
console of the machine. This switch allows you to
start or stop the spray operation. Press the switch to
enable or disable the spray system (
Left, Center, and Right Section Switches
The 3 section switches are located on the center
console in the front of the armrest (
). Toggle
each switch forward to turn the corresponding section
on and rearward to turn each off. When the switch is
in the O
N
position, an icon appears at the top of the
InfoCenter.
Note:
These switches affect the spray system only
when the master section switch is in the O
N
position.
Agitation Switch
The agitation switch is located on the center console
to the right of the seat (
). Toggle this switch
forward to turn on the agitation in the tank or rearward
to stop the agitation. When the switch is turned on, a
light on the switch illuminates. To operate the agitation
function, you must run the sprayer system pump and
you must run the engine above low idle.
Agitation-Bypass Valve
The agitation-bypass valve redirects the flow of fluid
to the sprayer-system pump when you turn off the
agitation function (
). The agitation-bypass
valve is located above the agitation valve. You can
adjust the bypass valve to ensure that the pressure
remains constant when cycling agitation on or off; refer
to
Calibrating the Agitation-Bypass Valve (page 29)
.
g194246
Figure 14
1.
Actuator (agitation valve)
3.
Flow meter
2.
Agitation-bypass-valve
handle
Flow Meter
The flow meter measures the flow rate of the fluid for
use by the InfoCenter system and when spraying in
the application rate mode (
Agitation-Throttle Valve
The agitation-throttle valve is a manually-operated ball
valve that controls flow to the agitation nozzles in the
main tank. This valve allows the sprayer operator to
control the sprayer-system pressure at the agitation
nozzles of the main tank when larger application rates
are required. The agitation-throttle valve is located
above the pump (
g032528
Figure 15
1.
Agitation-throttle-valve handle
19