Plumbing connection
06
INSTALLATION INSTRUCTIONS
• Brewer should be installed on a secure, level, surface capable of fully supporting the weight of the brewer, inclu-
ding the water retained in the brewer, and any fully loaded dispenser(s) that may be placed on the brewer.
• A potable water line (cold water) capable of consistently supplying the required minimum flow rate within the
noted pressure range is required at the install location.
• A grounded electrical connection to a circuit that meets the electrical specifications of the brewer and is protec-
ted by the appropriate size and type of breaker is required.
Brewer includes a combination strainer and flow control which MUST be attached to the rear plumbing connec-
tion. A metal swivel tube assembly is provided for attachment. The fitting plumbing connections are 1⁄4 male
flare. Inclusion of a coil of copper tubing in the water line will allow the brewer to be easily moved for cleaning the
counter underneath.
CAUTION:
POWER TO BREWER MUST BE OFF BEFORE PROCEEDING WITH PLUMBING INSTALLATION.
1. Flush water line before installing brewer. Brewer should be connected to
COLD WATER LINE ONLY.
2. Water pressure should be between 20 psi and 90 psi (.138 MPa and .620 MPa) . For less than a 25 ft run, use
1/4“ copper tubing and connect to 1/2“ or larger water line. For longer runs, use 3/8“ copper tubing & connect
to 1/2“ or larger water line and provide an adapter fitting for connection to the brewer. Recommended minimum
flow rate from water line is 1 gpm measured at the brewer connection point.
3. The use of saddle valves are not recommended as the size and shape of the hole made in the supply line may
restrict flow. However, if installed with saddle valve, the valve should have a minimum of 1/8“ port hole for up to
25 ft run, and 5/16“ port hole for over 25 ft runs.
4. Connect the strainer/flow control (provided) to brewer plumbing connection using the provided swivel tube
assembly. Note directional indication on the flow control.
5. Connect incoming water line to the inlet fitting of the strainer/flow control. Manufacturer recommends connec-
ting to copper tubing.
NOTE:
If a filter is provided for the brewer, follow the filter manufacturer’s recommendations for flushing prior to
connecting in line with brewer. Note the brewer has a filter tracking function available in the service menu of the