Brewing and Programming Outline
16
Select “Other Settings” to go to the ‘personalize, other settings’
screen. Note: Multiple languages are not available. Imperial or
Metric measurement units may be chosen. If imperial is selected,
volume will be programmed in fluid ounces and temperature in
degrees Fahrenheit. If Metric measure is chosen volume will be
programmed in milliliters and temperature in degrees Celsius. The
end of cycle/keypad beeper may be set to on or off. The energy
save mode has three choices: No energy saver, energy saver, or
power off. No energy saver maintains normal tank temperature
based on the lowest temperature setting of the active recipes.
Energy saver mode will set back the temperature that the tank is
maintained at and power off will shut down the tank heater. The
selected action will take place when the “Setback After” time has been reached. Use the + and – keys to change
the setback time. The autoarm key may be used to choose autoarm on, autoarm off, or autoarm global. If autoarm
on is chosen, the individual recipe tolerances will be used to determine if the tank is hot enough to start a brew
cycle. If autoarm global is selected, the value programmed on this screen will be used for all recipes, regardless
of a tolerance set in the individual recipes. Tap the autoarm tolerance key to increment the tolerance value to the
desired setting. Press finish to return to the personalize screen and then press finish to return to the program-
ming/service screen.
PARAMETERS
The ‘brewer parameters’ screen is meant for factory settings.
Contact factory for password authorization for these settings.
Press the “Brewer Parameters” key to go to the ‘brewer parameters’
screen. This screen is designed to allow the technician to tell the
control board how the machine has been configured or to disable
certain features that may be installed. Touch the various keys to
cycle through the available options and select the one that is
appropriate for your installation.Brew valve choices are for one or
two brew valves. If two valves are selected, one or both may be
activated for a particular brew cycle. This is not a common
configuration and does not include the hot water bypass valve.
Hot bypass and cold dilution may be set to installed or not installed. A hotwater dispense valve may be
installed for controlling a faucet or other hot water dispense outlet. Recipes may then be set to deliver premea-
sured volumes of hot water. Push and hold feature is automatically available when not brewing when a hot water
valve dispense valve is installed. The heating circuit may be programmed for either a solid state device which
would allow pulse heating, or for a mechanical relay, which would not but would be a more economical choice.
Warning – running a mechanical relay in pulsing mode will lead to premature failure of the component. Press
return to return to the programming/service screen.