2.5.4. RM Communication function setting
(RM-200SF: DIP switch 4 operation or RM-200SA: DIP switch 6 operation)
Set the RM communication function to the Automatic Setting (OFF) or 9600 bps Fixed (ON). Normally set to the
Automatic Setting (OFF). Communication may become unstable depending on conditions when cable length
between the unit and remote microphone is great. In such cases, set the switch to 9600 bps Fixed (ON). Be
sure to set the DIP switches of all remote microphones in the system to the same position.
Automatic Setting
9600 bps Fixed
OFF
(Default position)
ON
DIP Switch
RM Communication function