![Toa SX-2100AO Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/toa/sx-2100ao/sx-2100ao_installation-manual_1122349065.webp)
65
Step 2. Perform DIP switch settings on the CO circuit board.
The control output channels correspond to the DIP switches on the CO circuit board as follows.
Control output channels 1 – 8:
SW301
Control output channels 9 – 16:
SW302
Control output channels 17 – 24:
SW303
Control output channels 25 – 32:
SW304
CN201
CN101
CN308
CN307
CN306
CN305
CN304
CN303
CN302
CN301
SW301
SW302
SW303
SW304
SX-2000CO
CO circuit board
Front panel side
This setting causes the control output
channels 1 – 8 to remain OFF when
the general urgency all-call is made.
(Factory-preset).
This setting causes the control output
channel 1 to be turned ON when the
general urgency all call is made.
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
Step 3. Replace the top panel.
Note
Note the specific shapes of the different screws when replacing the top panel. (See Step 1.)