![Toa SX-2100AO Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/toa/sx-2100ao/sx-2100ao_installation-manual_1122349053.webp)
53
2.2.1. Module installation
Notes
• Make sure that the power is switched OFF before attaching or detaching modules.
• To avoid failures due to static electricity, do not touch the parts on the module circuit board.
• Ensure that the module is installed and secured with screws in the correct position.
• Cover idle slots with the blank panels attached to the SX-2000AI and SX-2100AI as shipped by the factory.
• Two silver slotted screws at the left and right sides of the front panel are handles used for module detachment.
Never rotate them because they do not function as screws.
The following figure shows an example of how the SX-200RM Remote Microphone Interface Module can be
mounted in the SX-2100AI unit.
2
1
Blank panel
SX-2100AI
Machine screw M3 x 6
(screw removed in Step 1)
Handle
Module
Step 1. Remove the blank panels attached to the SX-2000AI's or 2100AI's slots.
Note
Save the removed screws for use in Step 2.
Step 2. Mount the module.
Insert the module and fix it in place using the screws (Machine screws M3 x 6) removed in Step 1.
Usable modules are as follows:
• SX-200RM (Remote Microphone Interface Module)
• D-921F (Microphone/Line Input Module)
• D-922F (Microphone/Line Input Module)
• D-921E (Microphone/Line Input Module)
• D-922E (Microphone/Line Input Module)
• D-936R (Stereo Input Module)
• SX-200IP (IP Module, Refer to the instruction manual supplied with the module for details.)
Note
Do not use any modules other than those listed above.
2.2. SX-2000AI and SX-2100AI