![Toa SX-2100AO Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/toa/sx-2100ao/sx-2100ao_installation-manual_1122349043.webp)
43
1.11. RM-200RJ Terminal Unit
[Front]
1. RM Link Terminal [RM LINK]
Connect to the RM Link terminal of the RM-200SA
or SX-200RM.
2. Power Monitor Switch [ON/OFF]
Set to ON to enable the Power Monitor Indicator.
(Factory-preset: ON)
3. Power Monitor Indicator (Green)
Lights if the source voltage of the DC power input
exceeds the minimum operating voltage of the RM-
200SA when the Power Monitor Switch is set to
ON.
4. Screw Terminal Block
The Screw terminal block and RM link terminal are
internally connected in parallel. Numbers
1
through
8
indicated beside each terminal
correspond to the pin numbers of the RJ45
connector to be connected to the RM link terminal
(1).
• Audio monitor terminals [MONITOR H/C]
Connect the audio monitor line from the SX-2000
system to the RM-200SA.
• Audio output terminals [AUDIO H/C]
Connect the audio output line from the RM-
200SA to the SX-2000.
• RM communication terminals [DATA +/–]
Connect the control communication line between
the SX-2000 system and the RM-200SA.
• DC power input terminals [DC 24 V +/–]
Used to supply DC power from the SX-2000
system to the RM-200SA.
• Shield terminals [SHIELD]
Connect the shield wires for noise reduction or
for system control.
Be sure to connect at least one shield wire.
1
2
3
4