11. SPECIFICATIONS
11.1. SX-2000SM System Manager
Power Source
Usable power supply unit: VX-200PS
24 V DC (operational range: 20 V – 40 V DC)
Two power inputs construction enables redundant power supply.
Current Consumption
Under 1.1 A (maximum value in the power operating range)
Under 0.8 A (when operated on 24 V DC)
Indication/Operation
SX link indicator: 2
LAN indicator:
1
Mode indicator:
3 (EMERGENCY/STANDBY/CPU OFF)
Fault indicator:
3 (GENERAL/CPU/SX LINK)
Power indicator:
1 (POWER)
Run indicator:
1 (RUN)
Failure control key: 3 (FAULT ACK/FAULT RESET/LAMP TEST)
SX Link
Network I/F
2 100BASE-TX circuits, RJ45 connector
Matrix System
Specification
Bus:
16
Priority control: 512 steps
Audio input:
Max. 64 ch
Event log data: Max. 1,000 pieces
Audio output: Max. 256 zones
Failure log data: 100 pieces
Contact input: Max. 1416
Contact output: Max. 1416
Matrix System
Configuration
(Maximum number of units)
SX-2000AI/2100AI: 8 in total
SX-2000AO/2100AO: 32 in total
SX-2000CI:
32 (one per SX-2000AO/2100AO)
SX-2000CO:
32 (one per SX-2000AO/2100AO)
RM-200SF/200SA: 64 in total (up to 8 in total per SX-2000AI/2100AI)
Connection Cable/Device
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)
(Connect SX-2000AI,SX-2100AI, and SX-2000AO via the switching hub specified by TOA.)
Note: This network must be made completely independent from other LAN.
Number of Cascaded
Switching Hubs
Up to 7
Maximum Cable Distance 100 m (between this unit and a switching hub or between switching hubs)
LAN
Network I/F
1 10BASE-T/100BASE-TX circuit (selectable by automatic recognition),
RJ45 connector for maintenance use
Network Protocol
TCP/IP
Connection Cable
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)
Maximum Cable Distance 100 m (between this unit and a switching hub or between a switching hub and a
PC)
Analog Link
Input/Output Connector
Output: 2, RJ45 connector
Connection Cable
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)
(each one pair of audio wire, CPU OFF, control wire for system reset/start, and
connection check wire)
Maximum Cable Distance 800 m (total)
DS Link
Usable unit
VX-2000DS, VX-3000DS
Connector/Cable
2 interfaces, RJ45 Connector,
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)
Maximum Cable Distance 5 m
Failure Data Input
3 inputs (ACK/RES/LAMP), no-voltage make contact input,
open voltage: 24 V DC, short-circuit current: 2 mA, photo coupler input,
removable terminal block (12 pins)
Failure Data Output
4 outputs (CPU FAULT/GENERAL FAULT/CPU OFF/ BUZZER), C contact,
no-voltage make contact output, relay contact output (withstand voltage: 40 V DC,
control current: 2 – 300 mA), RJ45 connector
Control Input
8 inputs, no-voltage make contact input, open voltage: 24 V DC, short-circuit
current: 2 mA, photo coupler input, removable terminal block (12 pins)