11.6. SX-2000CI Control Input Unit
Power Source
24 V DC (operational range: 20 – 40 V DC),
2 channels of power inputs for accepting redundant power supply
Current Consumption
Under 0.7 A (maximum value in the power operating range)
Under 0.55 A (at 24 V DC operation)
Indication
Control Input indicators, Power indicator, CPU-OFF indicator, Fault indicator
Control Input
32 inputs, no-voltage make contacts, open voltage: 24 V DC,
short-circuit current: 2 mA, photo coupler inputs,
removable terminal blocks (16P x 4)
Surveillance Section for
the Control Input Lines
Connection resistance to make the function inactive: 20 kΩ ±5%
Connection resistance to make the function active: 10 kΩ ±5%
Connection cable: Twisted pair cable (shielded type is recommended)
Maximum cable distance: 10 m
CI/CO Link
Input/Output
Input: 1 channel, RJ45 connector
Output: 1 channel, RJ45 connector
Connection Cable
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)
(each one pair of data wire and control wire)
Maximum Cable Distance
800 m
24 V DC Output section
Connector
Input: 1 input, RJ45 connector
Output: 1 output, RJ45 connector
Connection Cable
Removable terminal block (2P)
Maximum Feeing Current
100 mA
Output Voltage
24 V DC within ±10%
Operating Temperature
0°C to 40°C
Operating Humidity
35% to 80% RH (no condensation)
Finish
Panel: Aluminum, black, alumite
Case: Surface-treated steel plate
Dimensions
482 (w) x 44 (h) x 331.5 (d) mm
Weight
3.6 kg
• Accessories
Removable terminal plug (16 pins) ........................................... 4
Removable terminal plug (4 pins) ............................................. 1
Removable terminal plug (2 pins) ............................................. 1
Rack mounting screw with plain washer (5 x 12) ..................... 4