13
(outputs "OUT1" or/and "OUT2") and starts tracing position and direction of pedestrian
movement in the turnstile access way, analyzing 6 IR barriers. As soon as pedestrian is behind the
blades line they close, the controller generates the signal "DETECTION OF ACCESS" of 0,3
second duration (outputs "OUT3" or "OUT4") and LED display is switched from green to red.
After the pedestrian turnstile access the controller removes the signal "ACCESS IS OCCUPIED"
and returns to "INITIAL STATE".
Fig. 6
– Appearance and configuration of controller AUIA.206.21.20.00
"FREE ACCESS"
The turnstile goes to this mode either upon command "FREE ACCESS А/В" arrived via
interface RS
-
485 from control panel or if during "SINGLE ACCESS" initiated by signal on input
"INP1" ("ACCESS А TO BE OPENED") or/and "INP2" ("ACCESS B TO BE OPENED") at the
end of 0,3 sec. after the signal "DETECTION OF ACCESS А" or "DETECTION OF ACCESS B"
is removed by controller, the signal on the relevant input "INP1" or "INP2" was not removed. In
this mode glass blades go to the turnstile pedestal slots, green arrow is blinking on LED display
from the side of authorized access. Thus every turnstile access is traced and the signal
"DETECTION OF ACCESS" of 0,3 second duration is generated to the relevant output («OUT3»
or "OUT4").
In this state the turnstile will be until arrival of command "CANCELLATION OF FREE
ACCESS" via interface RS
-
485 or until removal of signals from "INP1" or/and "INP2" depending
on the cause of switching to the free access mode.
1 - ON - when command is issued, the turnstile will
open for 5 seconds;
- OFF - when command is issued, the turnstile will
open for the time set in ACS;
2
-
ON
-
Outputs OUT1
-
5 will be NC;
-
OFF
-
Outputs OUT1
-
5 will be O;
3
-
5
-
Not usable;
6
-
Free access mode setting when blades are normally
closed is possible by closing IN1 and IN2. Signal on
IN1 or IN2 must be more than 6500 ms to set free
access;
-
ON
-
Activation of free access mode when blades
are normally closed;
-
OFF
-
Deactivation of free access mode when blades
are normally closed;
7
-
ON
-
Activation of free access mode A when blades
are normally closed;
Blades will be open when the first IR sensor is
crossed;
-
OFF
-
Deactivation of free access mode A when
blades are normally closed;
Blades will be open all the time;
8
-
ON
-
Activation of free access mode B when blades
are normally closed;
Blades will be open when the first IR sensor is crossed;
-
OFF
-
Deactivation of free access mode B when
blades are normally closed;
Blades will be open all the time;