_______________________________________________________________________________
CRAdd ON|OFF Default: OFF
Mode: Baudot RTTY Host: CR
_________________________________ Parameters: _________________________________
ON - Send <CR CR LF> in Baudot RTTY.
OFF - Send <CR LF> in Baudot RTTY (default).
_______________________________________________________________________________
The CRADD command permits you to set the PK-232's "newline" sequence so that an
additional carriage return is ADDed automatically at the end of each typed line.
When CRADD is ON the line-end sequence is <CR><CR><LF>. When CRADD is OFF the
line-end sequence is <CR><LF>. The double carriage return is required in some
RTTY services such as MARS. CRADD has no effect on received data.
_______________________________________________________________________________
CStatus [Short] Immediate Command
Mode: Packet Host: Not Supported
_______________________________________________________________________________
CSTATUS is an immediate command helpful in multiple connections.
When CSTATUS is typed, your monitor displays Link State of all ten logical
channels as well as the current input/output channel as follows:
NOT CONNECTED TO ANY STATION CONNECTED TO TWO STATIONS
cmd:cs cmd:cs
Ch. 0 - IO DISCONNECTED Ch. 0 - IO CONNECTED to WX1AAA
Ch. 1 - DISCONNECTED Ch. 1 - CONNECTED to WX1BBB
Ch. 2 - DISCONNECTED Ch. 2 - DISCONNECTED
Ch. 3 - DISCONNECTED Ch. 3 - DISCONNECTED
Ch. 4 - DISCONNECTED Ch. 4 - DISCONNECTED
Ch. 5 - DISCONNECTED Ch. 5 - DISCONNECTED
Ch. 6 - DISCONNECTED Ch. 6 - DISCONNECTED
Ch. 7 - DISCONNECTED Ch. 7 - DISCONNECTED
Ch. 8 - DISCONNECTED Ch. 8 - DISCONNECTED
Ch. 9 - DISCONNECTED Ch. 9 - DISCONNECTED
CSTATUS will give a short display if desired. CSTATUS SHORT (or CS S) displays
only the current input/output channel or those channels which are connected.
_______________________________________________________________________________
CText text Default: empty
Mode: Packet Host: CT
_________________________________ Parameters: _________________________________
text - Any combination of characters up to a maximum of 120 characters.
_______________________________________________________________________________
CTEXT is the "automatic answer" text sent when CMSG is ON. The message is sent
only when another station connects to you. A typical CTEXT message might be:
"I'm not available right now. Please leave a message on my MailDrop."
Clear CTEXT with "%", "&", "NO", "NONE" or "OFF", or simply set CMSG OFF.
8/91 A-31
Содержание PK-232 MBX
Страница 2: ...9 99 VA 02633 PK 232 OPERATING MANUAL PREFACE 8 91 P N 040 061 1...
Страница 137: ...PK 232 OPERATING MANUAL Pactor OPERATION The rest of this page is blank 2 93 11 16...
Страница 179: ...8 91 A 36b...
Страница 207: ...PK 232 OPERATING MANUAL COMMAND SUMMARY This page is blank 2 93 A 58b...
Страница 213: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 62b...
Страница 220: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 65d...
Страница 225: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 68b...
Страница 243: ...PK 232 OPERATING MANUAL APPENDIX B 4 91 B 1...
Страница 244: ...PK 232 OPERATING MANUAL APPENDIX B 4 91 B 2...
Страница 245: ...PK 232 OPERATING MANUAL APPENDIX C APPENDIX C PARTS PICTORIAL DISPLAY BOARD 4 91 C 1...
Страница 253: ...D...
Страница 254: ...D...
Страница 255: ...D...
Страница 256: ...D...
Страница 257: ...D 9 99 E 10...