Beacon EVERY|AFTER "n" Default: EVERY 0 (00 sec.)
Mode: Packet Host: BE
_________________________________ Parameters: _________________________________
EVERY - Send the beacon at regular intervals.
AFTER - Send the beacon after the specified time interval without activity.
"n" - 0 to 250 sets beacon timing in ten-second intervals.
"0" - Zero turns off the beacon (default).
_______________________________________________________________________________
The BEACON command sets the conditions under which your beacon will be sent.
A beacon frame contains the text that you've typed into the BTEXT message in a
packet addressed to the UNPROTO address. When the keyword EVERY is specified a
beacon packet is sent every "n" times ten seconds. When AFTER is specified, a
beacon is sent after "n" times ten seconds have passed without packet activity.
If you set the BEACON timing less than "90" - a value judged as too short for
busy channels - you'll see the following message at each command prompt:
WARNING: BEACON too often
_______________________________________________________________________________
BItinv "n" Default: $00
Mode: RTTY Host: BI
_________________________________ Parameters: _________________________________
"n" - 0 to $1F, (0 to 31 decimal) specifies a number to be exclusive-ORed
with every received Baudot character. BITINV 0 is plain text.
_______________________________________________________________________________
Bit inversion is used to prevent listeners from reading some commercial Baudot
transmissions. Usually either 2 or 3 bits of each character are inverted to
give the appearance of an encrypted transmission. Try different settings of
BITINV on a Baudot signal after the baud rate has been determined. If you are
interested encrypted transmissions try experimenting with the 5BIT command.
_______________________________________________________________________________
BKondel ON|OFF Default: ON
Mode: All Host: BK
_________________________________ Parameters: _________________________________
ON - The sequence <BACKSPACE><SPACE><BACKSPACE> is echoed when a character
is deleted from the input line.
OFF - The <BACKSLASH> character <\> is echoed when a character is deleted.
_______________________________________________________________________________
BKONDEL determines how character deletion is displayed in Command or Converse
mode. When BKONDEL is ON (default) the <BACKSPACE><SPACE><BACKSPACE> sequence
is produced which updates the video display screen erasing the character.
On a printing terminal the <BACKSPACE><SPACE><BACKSPACE> sequence will result in
overtyped text. Set BKONDEL OFF if you have a paper-output display, or if your
terminal does not respond to the <BACKSPACE> character <CTRL-H>. When BKONDEL
is OFF the PK-232 displays a <BACKSLASH> for each character you delete. You can
get a display of the corrected input by typing the REDISPLAY-line character.
4/91 A-20
Содержание PK-232 MBX
Страница 2: ...9 99 VA 02633 PK 232 OPERATING MANUAL PREFACE 8 91 P N 040 061 1...
Страница 137: ...PK 232 OPERATING MANUAL Pactor OPERATION The rest of this page is blank 2 93 11 16...
Страница 179: ...8 91 A 36b...
Страница 207: ...PK 232 OPERATING MANUAL COMMAND SUMMARY This page is blank 2 93 A 58b...
Страница 213: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 62b...
Страница 220: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 65d...
Страница 225: ...PK 232 OPERATING MANUAL COMMAND SUMMARY The rest of this page is blank 2 93 A 68b...
Страница 243: ...PK 232 OPERATING MANUAL APPENDIX B 4 91 B 1...
Страница 244: ...PK 232 OPERATING MANUAL APPENDIX B 4 91 B 2...
Страница 245: ...PK 232 OPERATING MANUAL APPENDIX C APPENDIX C PARTS PICTORIAL DISPLAY BOARD 4 91 C 1...
Страница 253: ...D...
Страница 254: ...D...
Страница 255: ...D...
Страница 256: ...D...
Страница 257: ...D 9 99 E 10...