5.3 Device Setup Commands
Command List
Command
Description
:PRANGE[1,2]
Set the channel 1/2 power range.
:PRANGE[1,2]?
Query the channel 1/2 power range.
:PRANGE[1,2]:MIN?
Query the channel 1/2 minimum settable power range.
:PRANGE[1,2]:MAX?
Query the channel 1/2 maximum settable power range.
:IRANGE[1,2]
Set the channel 1/2 current range.
:IRANGE[1,2]?
Query the channel 1/2 current range.
:IRANGE[1,2]:MIN?
Query the channel 1/2 minimum settable current range.
:IRANGE[1,2]:MAX?
Query the channel 1/2 maximum settable current range.
:URANGE[1,2]
Set the channel 1/2 voltage range.
:URANGE[1,2]?
Query the channel 1/2 voltage range.
:URANGE[1,2]:MIN?
Query the channel 1/2 minimum settable voltage range.
:URANGE[1,2]:MAX?
Query the channel 1/2 maximum settable voltage range.
:ERANGE[1,2]
Set the channel 1/2 energy range.
:ERANGE[1,2]?
Query the channel 1/2 energy range.
:ERANGE[1,2]:MIN?
Query the channel 1/2 minimum settable energy range.
:ERANGE[1,2]:MAX?
Query the channel 1/2 maximum settable energy range.
:VRANGE[1,2]
Set the channel 1/2 pyroelectric voltage range.
:VRANGE[1,2]?
Query the channel 1/2 pyroelectric voltage range.
:VRANGE[1,2]:MIN?
Query the channel 1/2 minimum settable pyroelectric voltage range.
:VRANGE[1,2]:MAX?
Query the channel 1/2 maximum settable pyroelectric voltage range.
:WAVEL[1,2]:VAL
Set the wavelength for channel 1/2
:WAVEL[1,2]:VAL?
Query the currently used wavelength for channel 1/2
:WAVEL[1,2]:RNG?
Query the channel 1/2 wavelength range
:ATTEN[1,2]:VAL
Set the channel 1/2 power attenuation
:ATTEN[1,2]:VAL?
Query the channel 1/2 power attenuation
:ATTEN[1,2]:RNG?
Query the channel 1/2 power attenuation range
:PDBANDW[1,2]
Set the channel 1/2 photodiode input/photodiode sensor bandwidth.
:PDBANDW[1,2]?
Query the channel 1/2 photodiode input/photodiode sensor bandwidth.
:PDPOL[1,2]
Set the channel 1/2 photodiode input polarity
:PDPOL[1,2]?
Query the channel 1/2 photodiode input polarity
:PDRESP[1,2]:VAL
Set the photodiode responsivity for channel 1/2
:PDRESP[1,2]:VAL?
Query the currently used photodiode responsivity for channel 1/2
:PDRESP[1,2]:RNG?
Query the channel 1/2 photodiode responsivity range
:PDBIAS[1,2]
Set the channel 1/2 photodiode input BIAS state
:PDBIAS[1,2]?
Query the channel 1/2 photodiode input BIAS state
:PDBIAS[1,2]:VAL
Set the channel 1/2 photodiode input BIAS voltage
:PDBIAS[1,2]:VAL?
Query the channel 1/2 photodiode input BIAS voltage
:PDBIAS[1,2]:RNG?
Query the channel 1/2 photodiode input BIAS voltage range
:THACCEL[1,2]
Set the channel 1/2 thermopile accelerator state.
:THACCEL[1,2]?
Query the channel 1/2 thermopile accelerator state.
Содержание PM320E
Страница 1: ...Thorlabs Instrumentation Optical Power and Energy Meter PM320E Operation Manual 2016...
Страница 2: ...Copyright 2016 Thorlabs GmbH Version Date Item No 2 1 10 Mar 2016 M0009 510 618...
Страница 5: ...67 8 6 Thorlabs End of Life Policy 68 8 7 Thorlabs Worldwide Contacts...
Страница 13: ...2016 Thorlabs GmbH 2 Getting Started 11 Display Energy Statistics CH2 Display Energy Histogram CH1...