![THORLABS PM320E Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/thorlabs/pm320e/pm320e_operation-manual_1110983031.webp)
© 2016 Thorlabs GmbH
5 Command Reference
29
Wait Command
Command format:
*WAI
Description:
This command is required for IEEE488 compatibility and has no effect. (see also
IEEE488.2-1992-§10.39).
Reset Command
Command format:
*RST
Description:
This command resets the device. (see also IEEE488.2-1992-§10.32).
Service Request Enable Command
Command format:
*SRE <DECIMAL NUMERIC PROGRAM DATA>
Description:
Sets the device’s Service Request Enable Register (see also IEEE488.2-1992-
§10.34 and chapter ‘Status Reporting’ in this document).
Service Request Enable Query
Command format:
*SRE?
Response format:
<NR1 NUMERIC RESPONSE DATA>
Description:
Queries the device’s Service Request Enable Register (see also IEEE488.2-
1992-§10.35 and chapter ‘Status Reporting’ in this document).
Read Status Byte Query
Command format:
*STB?
Response format:
<NR1 NUMERIC RESPONSE DATA>
Description:
Queries the device’s Status Byte (see also IEEE488.2-1992-§10.36 and chapter
‘Status Reporting’ in this document).
Standard Event Status Enable Command
Command format:
*ESE <DECIMAL NUMERIC PROGRAM DATA>
Description:
Sets the device’s Standard Event Status Enable Register (see also IEEE488.2-
1992-§10.10 and chapter ‘Status Reporting’ in this document).
Standard Event Status Enable Query
Command format:
*ESE?
Response format:
<NR1 NUMERIC RESPONSE DATA>
Description:
Queries the device’s Standard Event Status Enable Register (see also
IEEE488.2-1992-§10.11 and chapter ‘Status Reporting’ in this document).
Standard Event Status Register Query
Command format:
*ESR?
Response format:
<NR1 NUMERIC RESPONSE DATA>
Description:
Queries the device’s Standard Event Status Register (see also IEEE488.2-1992-
§10.12 and chapter ‘Status Reporting’ in this document).
Clear Status Command
Command format:
*CLS
Prerequisite:
None
Description:
Clears the following device’s status registers (see also IEEE488.2-1992-§10.3):
·
Standard Event Status Register
·
Device Error Event Register
·
Device Operation Event Register
·
Device Error Queue
Содержание PM320E
Страница 1: ...Thorlabs Instrumentation Optical Power and Energy Meter PM320E Operation Manual 2016...
Страница 2: ...Copyright 2016 Thorlabs GmbH Version Date Item No 2 1 10 Mar 2016 M0009 510 618...
Страница 5: ...67 8 6 Thorlabs End of Life Policy 68 8 7 Thorlabs Worldwide Contacts...
Страница 13: ...2016 Thorlabs GmbH 2 Getting Started 11 Display Energy Statistics CH2 Display Energy Histogram CH1...