Heat Pump Manual
22
INSTALLATION
Temperature Sensing
Water temperature probes
The unit will be supplied with a 20 meter water temperature probe.
The heat pump will be supplied with a 20m temperature probe that is designed to measure
the temperature in the central storage tanks and this is a part of the installation process. If this
temperature probe is not installed properly the water temperature in the tank may not reach
the set point. This probe is used by the software in the controller for the main temperature
sensing and the operation of the unit relies on this probe. The temperature displayed on the
screen of the controller is the storage tank temperature
The temperature displayed on the red screen display on the exterior of the unit is the return
water temperature from the storage tank
The swimming pool heat pumps are not supplied with the same heat sensor
– the swimming
pool heat pumps main temperature sensor is installed in the return water line so unlike the
normal units the unit does not need the sensor installed remotely. The normal 20m
temperature probe will not be supplied with the unit
– the unit can be plumbed in an will run as
a self-contained unit.
Installation of the Water Path
Before connecting the make-up water, check the suction pressure on in the heat pump
is above 200kPa. A refrigeration mechanic can do this with gauges.
By removing the front panel access point can be seen under on the suction line under
the electrical box. Connect the low pressure side gauge to one of the Schrader valves
and test the pressure in the system.
Содержание THW100
Страница 17: ...Heat Pump Manual 17 DIMENSIONS THW30 and THW40 THW50 and THW60 ...
Страница 18: ...Heat Pump Manual 18 DIMENSIONS THW80 THW100 AND THW130 ...
Страница 19: ...Heat Pump Manual 19 DIMENSIONS THWW20 to THWW40 Water to Water THWW50 THWW60 and THWW80 Water to Water ...
Страница 58: ...Heat Pump Manual 58 WIRING DIAGRAM 20kW HEAT RECOVERY COIL ...