32
Malfunctions
Possible causes
Remedy
Chap.
At low
temperatures:
If equipped with a
stop solenoid or
automatic electri-
cal shutdown sys-
tem (additional
equipment)
6.2.
Engine fires but
does not run.
Automatic
electrical shut-off
device
(optional extra)
6.3.
Starter motor does
not operate or en-
gine does not turn
over.
Starting speed below 400 min
-1
- Viscosity of oil too high.
- Battery charge too low.
Solenoid faulty and/or fault in
the electrical system.
Speed control lever not moved
far enough towards „START“.
Equipment not disengaged.
Fuel filter blocked.
One of the automatic shut-
down’s monitoring elements has
initiated a stop signal.
(See also Chapter 6.4.)
Fault in the electrical system:
- Battery and/or other cables
incorrectly connected up.
- Cable connections loose and/or
oxidised.
- Battery faulty and/or flat.
- Starter motor faulty.
- Faulty relays, monitoring
element.
Change lubricating oil and add
oil of the correct viscosity class.
Check the battery, if necessary
contact a service station.
See workshop manual.
Move lever to „START“ position.
Disengage engine from equip-
ment if possible.
Renew fuel filter.
Localise the monitoring element
responsible and clear the fault,
or contact a HATZ service station.
Check electrical system and its
component. See also the work-
shop manual.
5.3.2.
4.1.1.
7.
4.2.1.
5.4.1.
7.
Содержание LEO 15 GT
Страница 12: ...General 13 02 2013 Aerial access platform Leo15GT 2012 12 ...
Страница 37: ...3914 0095 3914 0021 3914 0054 3914 0021 3914 0053 ...
Страница 39: ......
Страница 58: ...Structure and function 13 02 2013 Aerial access platform Leo15GT 2012 54 ...
Страница 66: ...Transport and storage 13 02 2013 Aerial access platform Leo15GT 2012 62 ...
Страница 106: ...Operation 13 02 2013 Aerial access platform Leo15GT 2012 102 ...
Страница 145: ...Appendix Appendix 13 02 2013 Aerial access platform Leo15GT 2012 141 ...
Страница 146: ...Appendix 13 02 2013 Aerial access platform Leo15GT 2012 142 ...
Страница 148: ...Appendix 13 02 2013 Aerial access platform Leo15GT 2012 144 ...
Страница 149: ...A Combustion engine Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 145 ...
Страница 150: ...Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 146 ...
Страница 151: ...A 1 Gasoline engine Robin Subaru EX 21 Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 147 ...
Страница 152: ...Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 148 ...
Страница 165: ...A 2 Diesel engine Hatz 1B30 optional Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 161 ...
Страница 166: ...Combustion engine 13 02 2013 Aerial access platform Leo15GT 2012 162 ...
Страница 167: ...INSTRUCTION BOOK 43380207 ENG 10 05 3 Printed in Germany 33 1B20 1B27 1B30 1B40 1B50 ...
Страница 204: ......
Страница 205: ...B Circuit diagram Circuit diagram 13 02 2013 Aerial access platform Leo15GT 2012 201 ...
Страница 206: ...Circuit diagram 13 02 2013 Aerial access platform Leo15GT 2012 202 ...
Страница 207: ...C Hydraulic plan Hydraulic plan 13 02 2013 Aerial access platform Leo15GT 2012 203 ...
Страница 208: ...Hydraulic plan 13 02 2013 Aerial access platform Leo15GT 2012 204 ...