Chapter 1: Introduction
R-Engine-D
Power On or Reset
YES
Go to Application Code CS:IP
STEP 2
ACTF menu sent out through ser0
STEP 1
Step 2 jumper
NO
set?
CS:IP in EEPROM:
0x10=CS high byte
0x11=CS low byte
0x12=IP high byte
0x13=IP low byte
at 19200 baud
Figure 1.2 Flow chart for ACTF operation
The “ACTF boot loader” resides in the top protected sector of the 256KW on-board Flash chip (29F400).
At power-on or RESET, the “ACTF” will check the STEP 2 jumper. If STEP 2 jumper is not installed, the
ACTF menu will be sent out from serial port0 at 19200 baud. If STEP 2 jumper is installed, the “jump
address” located in the on-board serial EE (see App. E) will be read out and the CPU will jump to that
address. A DEBUG kernel “re40_115.hex” can be downloaded to a starting address of “0xFA000” of the
256KW on-board flash chip.
1-4