MAINTENANCE
55
7400 (GM) 330970 (3--05)
SCRUB BRUSH IDLER
Each scrub brush idler has one grease fitting. The
scrub brush idlers must be lubricated every 100
hours of operation. Use Lubriplate EMB grease
(Tennant part no. 01433--1).
HYDRAULICS
HYDRAULIC FLUID RESERVOIR
The reservoir is located in front left corner of the
machine.
Mounted on top of the reservoir is a filler cap with
a built-in breather and fluid level dipstick. Replace
the cap every 800 hours of operation.
Check the hydraulic fluid level at operating
temperature every 100 hours of operation. The
end of the dipstick is marked with FULL and ADD
levels to indicate the level of hydraulic fluid in the
reservoir.
Lubricate the filler cap gasket with a film of
hydraulic fluid before putting the cap back on the
reservoir.
ATTENTION! Do not overfill the
hydraulic fluid reservoir or operate the
machine with a low level of hydraulic
fluid in the reservoir. Damage to the
machine hydraulic system may result.
Drain and refill the hydraulic fluid reservoir with
new hydraulic fluid every 800 hours of operation.
The hydraulic fluid filter is located at the bottom of
the engine compartment. Replace the filter
element every 800 hours of operation.
The reservoir has a built-in strainer outlet that
filters hydraulic fluid before it enters the system.
Replace the strainer every 800 hours of operation.
Содержание 7400