ELECTRICAL
4-29
5400 330735 (3–01)
4. Remove the three hex screws holding the
squeegee lever bracket assembly to the left
side of the solution tank.
5. Locate the vacuum fan switch at the middle
of the lever bracket assembly. Mark and
disconnect the wires leading to the switch.
6. Remove the two pan screws and nuts
holding the vacuum fan switch to the
bracket. Remove the switch.
7. Install the new switch onto the bracket.
Reinstall the pan screws and nuts. Tighten
the hardware.
8. Reconnect the wires to the new switch.
See electrical schematic in this section.
9. Position the squeegee lever bracket
assembly to the left side of the solution tank.
Reinstall the three hex screws and tighten to
18 – 20 Nm (15 – 18 ft lb).