ELECTRICAL
4-73
5400 330735 (3–01)
YES
NO
BOTH BRUSHES DO NOT OPERATE WITH BRUSH DECK DOWN
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO BATT. NEG.
(TWIST ROLL GRIPS
DURING TEST)
CHECK BRUSH DECK AND
FLOOR SURFACE FOR
CAUSE OF OVERLOAD
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
POSITIVE BATTERY
CABLE TO BATT. NEG.
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO NEGATIVE
STAND–OFF (TWIST ROLL
GRIPS DURING TEST)
RESET CIRCUIT
BREAKERS 1 AND 2
BRUSHES WORK?
NO
YES
REPAIR OR REPLACE
POSITIVE BATTERY
CABLE
GO TO
NEXT PAGE
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO 23 BLK
(TWIST ROLL GRIPS
DURING TEST)
NO
YES
NO
YES
NO
YES
REPAIR OR REPLACE
23 BLK
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO 27 BLK
(TWIST ROLL GRIPS
DURING TEST)
REPAIR OR REPLACE
27 BLK
GO TO
BRUSH 1 OR 2
DOES NOT OPERATE
YES
NO
IF ONE MOTOR WORKS:
GO TO – ONE BRUSH DOES
NOT OPERATE
START HERE
REPAIR OR REPLACE
NEGATIVE BATTERY
CABLE
Содержание 5400
Страница 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Страница 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Страница 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Страница 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Страница 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Страница 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Страница 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Страница 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Страница 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Страница 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Страница 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Страница 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Страница 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...