ELECTRICAL
4-21
5400 330735 (3–01)
TO REPLACE RESETTABLE CIRCUIT
BREAKER
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
1. Open the instrument panel. See TO
ACCESS INSTRUMENT PANEL
instructions.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
2. Locate the resettable circuit breakers at the
center of the instrument panel box.
3. Mark and disconnect the wires leading to the
circuit breaker that needs to be changed.
4. Loosen and remove the breakers mounting
nut located on the front side of the switch
panel.
5. Connect the wires to the new circuit breaker.
See electrical schematic in this section.
6. Install the new breaker into the panel. DO
NOT over tighten the mounting nut or
damage may occur to the breaker.
7. Reinstall the instrument panel. See TO
ACCESS INSTRUMENT PANEL
instructions.
8. Operate the machine. Check the scrub
brush for proper operation.
Содержание 5400
Страница 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Страница 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Страница 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Страница 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Страница 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Страница 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Страница 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Страница 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Страница 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Страница 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Страница 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Страница 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Страница 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...